Article

Coronary Arteries and Sirolimus-eluting Stents - Applications, Benefits and Future Potential

Register or Login to View PDF Permissions
Permissions× For commercial reprint enquiries please contact Springer Healthcare: ReprintsWarehouse@springernature.com.

For permissions and non-commercial reprint enquiries, please visit Copyright.com to start a request.

For author reprints, please email rob.barclay@radcliffe-group.com.
Average (ratings)
No ratings
Your rating
Copyright Statement:

The copyright in this work belongs to Radcliffe Medical Media. Only articles clearly marked with the CC BY-NC logo are published with the Creative Commons by Attribution Licence. The CC BY-NC option was not available for Radcliffe journals before 1 January 2019. Articles marked ‘Open Access’ but not marked ‘CC BY-NC’ are made freely accessible at the time of publication but are subject to standard copyright law regarding reproduction and distribution. Permission is required for reuse of this content.

It took great courage around 30 years ago to tackle stenotic lesions within a diseased coronary artery using the percutaneous approach in an unanaesthetised human being. Since then, unbelievable progress and research have been taking place worldwide in a continuum that never seems to end. Percutaneous coronary intervention (PCI) is, for the responsible interventional cardiologist, not only an appealing method of coronary revascularisation but also a permanent challenge, as the technical progress must be balanced against the perceived and foreseeable risks to the patient. Stents were conceived to make balloon angioplasty safer and more effective. They controlled elastic recoil and negative remodelling, but also stimulated the cellular mechanisms yielding to in-stent restenosis. Restenosis after bare-metal stenting (BMS) is mostly due to neointimal proliferation. It was a pure mechanical solution to an important biological problem. The development of an antiproliferative drug-coated stent followed extensive research on the understanding of vascular biology, pharmacology and experimental and clinical research. Sirolimus (rapamycin) and paclitaxel target the cell cycle, inhibiting the effects of injury-mediated growth factors and cytokines that produce vascular smooth muscle proliferation and intimal hyperplasia.

The Cypher® stent utilises a non-erodable methacrylate co-polymer matrix for controlled endovascular delivery of the drug to the arterial tissue. Sirolimus is blended with the polymer and a thin coating is applied to the surface of the Bx Velocity™ Cordis stent. A second coat of drug-free polymers serves as a diffusion barrier. The quantity of sirolimus loaded onto each stent is approximately 140mg/cm2, and the system provides controlled release of sirolimus over a period of four weeks.

The sirolimus-eluting stent (SES) was the first stent-based pharmacological therapy approved for the prevention of restenosis and the first to be approved by the European Community. It was introduced into clinical practice in 2002, bringing in the current drug-eluting stent (DES) era of interventional cardiology. Together with the paclitaxel-eluting stent (PES), approved later, they form the so-called first-generation DES. A pivotal randomised controlled trial (RCT) was the Randomized Study with the Sirolimus-coated Bx Velocity Balloon- Expandable Stent in the Treatment of Patients with De Novo Native Coronary Artery Lesions (RAVEL),1 in which 238 patients were randomised to a single SES and a BMS. The result was an unexpected outcome of 0% restenosis in the SES group compared with 26% restenosis in the BMS group at six months. This was followed by the larger (1,058 patients) Sirolimus-eluting Stent in De Novo Native Coronary Lesions (SIRIUS) trial2 in the US, and the E-SIRIUS3 (n=352) in Europe and C-SIRIUS4 (n=100) in Canada. The combined data from the last three studies (NEW-SIRIUS) reported a 5.1% in-lesion restenosis rate.

The true measure of the efficacy of DES, representing the best angiographic surrogate of neointimal proliferation with the unique ability to separate it from other procedural and intrinsic vessel variables, is in-stent late luminal loss (LL). It can reliably predict the restenosis propensity and the clinical consequence of target lesion revascularisation (TLR).5 The SES has always showed the smallest in-stent LL compared with other DES.

The on-label indications for the Cypher SES were single de novo lesions in patients with stable coronary artery disease (CAD) in vessels with reference diameters between 2.5 and 3.5mm and in lesions ≤30mm. Stimulated by the remarkable results of the initial studies, cardiologists have progressively expanded the use of SES to almost all clinical situations and more complex lesions. The off-label use of DES is current clinical practice, and may account for as many as 75% of procedures.

An impressive number of publications have dealt with SES implantation in diabetic patients, patients with acute myocardial infarction (MI), very small vessels (<3.0mm), very long lesions (>30mm), multivessel disease, bifurcation lesions, unprotected left main disease, chronic total occlusions, saphenous vein grafts and BMS in-stent restenosis. Many of the data collected are derived from single or multicentre studies and from registries, but in some cases RCTs have been performed.

Data from these RCTs have confirmed the efficacy of SES versus BMS and PES in significantly reducing restenosis rates and the need for further reintervention (TLR). Three RCTs were in acute MI,6–8 two in small vessels9,10 (the Sirolimus-Eluting and an Uncoated Stent in the Prevention of Restenosis in Small Coronary Arteries [SES-SMART]9 trial also showed a decreased incidence of MI comparing SES with BMS, and in the Intracoronary Drug-Eluting Stenting to Abrogate Restenosis in Small Arteries-III [ISAR-SMART III]10 SES was seen to be superior to PES), one in long lesions (Sirolimus-eluting Stent Versus Paclitaxel-eluting Stent for Patients with Long Coronary Artery Disease [Long-DES-II])11 and in the first and only RCT in saphenous vein grafts (Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent [RRISC]).12 Finally, a meta-analysis of four RCTs13 (three with SES and one with PES) have confirmed the superiority of DES versus balloon angioplasty or vascular brachytherapy in 1,230 patients with BMS in-stent restenosis.

Despite the undisputable efficacy of SES based on the extensive clinical research performed, our concern lately has been focused on DES safety. The real possibility of late stent thrombosis has created the current period of reflection regarding indications, limitations and future developments. Safety data are currently derived from the initial RCTs that allowed the introduction of SES into clinical practice, as they offer the longest follow-up available. A recent pooled analysis14 of the initial four RCTs (1,748 patients) with SES1–4 with a follow-up at four years was reassuring in terms of safety for on-label indications. The survival rate at four years was 93.3% in the SES group and 94.6% in the BMS group (p=0.28), and there were no differences in the rates of myocardial infarction and stent thrombosis. The only significant survival difference was found in diabetic patients in favour of the BMS group (87.8 versus 95.6%; p=0.008), and this was due to an increase in both cardiovascular and non-cardiovascular deaths. Using the protocol definition of stent thrombosis, the rate of thrombosis was 1.2% with the SES versus 0.6% with BMS (p=0.20); using the Academic Research Consortium (ARC) definitions of ‘definitive’ or ‘probable’ stent thrombosis, the rate was 1.5% with SES versus 1.7% with BMS (p=0.70). The incidence of definite or probable events occurring one to four years after implantation was 0.9% in the SES group and 0.4% in the BMS group.15

An analysis of data on 4,958 patients enrolled in 14 RCTs comparing SES with BMS16 (mean follow-up interval 12.1–58.9 months) showed that the risk of death (hazard ratio [HR] 1.03, 95% confidence interval [CI] 0.80–1.30) or the combined risk of death and myocardial infarction (HR 0.97; 95% CI 0.81–1.16) was similar in patients receiving SES or BMS. A significant advantage of SES over BMS was found in the combined risk of death, myocardial infarction and reintervention (HR 0.43, 95% CI 0.34–0.54). Regarding safety, there was no significant difference in the overall risk of stent thrombosis with SES versus BMS (HR 1.09, 95% CI 0.64–1.86), but there was evidence of a slight increase in the risk of stent thrombosis associated with SES after the first year.

Further analysis17,18 has confirmed that mortality is similar with SES, PES and BMS. SES has the lowest risk of MI in that there were no significant differences in the overall risk of definite stent thrombosis and that the risks of late stent thrombosis and MI probably increased with PES. Safety concerns are probably justified regarding the off-label use of DES. Data from the National Heart, Lung and Blood Institute (NHLBI) Dynamic Registry19 in 6,551 patients using DES for off-label indications showed a decreased risk of death or myocardial infarction (7.5 versus 11.6% with BMS; p<0.001), and a lower rate of repeat revascularisation at one year (12.7 versus 17.5% with BMS; p<0.001).

These data are somewhat rewarding, but we should take into consideration the fact that late stent thrombosis is a real possibility, late follow-up data are not yet available and our current knowledge regarding the potential mechanisms for stent thrombosis is still limited. For clinical purposes common sense recommends maintenance of dual antiplatelet therapy for a more extensive period of time, even if it is recognised that some patients are resistant to one or both antiagregant drugs; consideration of the risks of stent thrombosis for some patient and lesion subsets is also recommended. This was actually the recommendation of the American Heart Association/American College of Cardiology/Society for Cardiovascular Angiography and Interventions/American Cancer Society/American Diabetes Association (AHA/ACC/SCAI/ACS/ADA) Science Advisory Committee.20

Bearing in mind the the issue of stent thrombosis with DES, we should consider the arteries into which stents are implanted and the many unknown factors related to placing an active DES into an artery, a combination that certainly interferes with the healing response. Technical problems at the time of stent implantation, such as stent malapposition and underexpansion, have been well demonstrated by intravascular ultrasound (IVUS), and could be a cause of late stent thrombosis. SES underexpansion can be observed in up to 67% of cases,21 but late stent malapposition could not be related to stent thrombosis, death or MI after DES implantation.22 Late incomplete stent apposition may lead to aneurysm formation.23 A recent randomised study suggests that direct stenting is associated with reduced microvascular dysfunction induced by PCI rather than conventional pre-dilation stenting.24 Will the long-term effect of stenting eliminate the possibility of positive remodelling if atherosclerosis progresses?

DES induces complex interactions between shear stress and inhibition of neointimal growth. The main components of a DES, the polymer and the drug, may be directly involved in the delayed healing, inflammation (patient-related factors such as genetic control of inflammatory responses or the individual response to sirolimus or paclitaxel), hypersensitivity (to the drug or the polymer) and aneurysm formation that follows its implantation. A serial quantitative IVUS study25 over four years after implantation of an SES showed that between two and four years peri-stent tissue shrank, with a concomitant increase in echogenicity. This suggests that late chronic artery responses may evolve for up to four years.

The fact that the neointima does not significantly change between two and four years may suggest that the biological phenomenon of a delayed healing response has begun to subside. There is some evidence to suggest that a hypersensitivity reaction can lead to delayed endothelisation and destruction of the medial vessel wall, which may cause late acquired stent malapposition.26

An antiarteriogenic effect of DES negatively affecting collateral growth has also been described27 on average six months after stent implantation, which, considering the protective nature of collateral vessels, could lead to more serious cardiac events in the presence of an abrupt coronary occlusion. In this context, the effect of sirolimus appears to be less pronounced than that of paclitaxel. A major concern is the effect of DES on incomplete endothelisation and endothelial dysfunction. However, there is only limited evidence to support the notion that uncovered stent struts as a consequence of delayed re-endothelialisation are implicated in the process of late stent thrombosis. Angioscopic studies have shown delayed neointimal stent coverage and slower thrombus disappearance in SES than in BMS.28,29 A histological study of tissue obtained by atherectomy of in-stent restenosis cases from BMS and DES (10 SES and nine PES) showed that a persistent incomplete healing response, which occured as late as two years, was present only in DES. The amount of fibrinoid was greater in PES than in SES (17 versus 5%; p=0.026), and patients with PES in-stent restenosis presented clinically more with unstable angina.30

Although limited and short-term, studies of endothelial function after SES raise interesting questions about the future and deserve further investigation. SES has been associated with exercise-induced paradoxic vasoconstriction of the adjacent vessel segments, although vasodilatory response to nitroglycerin was maintained. This endothelial dysfunction was attributed to the antiproliferative drug diffusing from the stent to the peri-stent region.31 Local endothelial-dependent vasoconstriction after acetylcholine infusion and nitrates after SES implantation have also been described, and are greater than with BMS and in control vessels, particularly arterial segments distal to stents.32,33

These are some of many unsolved issues still linked to the permanent implantation of SES and other DES into the coronary arteries. First-generation DES will have to be used as controls for newer stents in RCTs, but post-marketing surveillance of any new device is mandatory to monitor safety, particularly in Europe.

What we have learned with the SES is that it is very effective in reducing lesions, late LL and restenosis rates, and represents a breakthrough in interventional cardiology. In spite of also decreasing TLR in a great variety of clinical situations and in more complex lesions that overpass the on-label approved indications, it has not been shown to be a major contributor to patient survival. This is not unexpected, as stents were first aimed at controlling symptoms. First-generation DES may have revolutionised our perception of treating CAD. We are continuously learning and, so far, the benefits achieved through reduction in restenotic rates markedly outweigh any small risk of stent thrombosis. CAD is progressive and part of a more generalised atherosclerotic process and, above all, requires continued and well-established medical therapies such as statins, ACE inhibitors, antiplatelet drugs and control of risk factors.

There will be continued efforts to overcome current DES failures and the limitations of new technologies, stents, drugs and coatings. It seems clear that abolishing neointimal hyperplasia is no longer the ultimate goal. The perfect carrier for biocompatible absorbable coatings, new drugs targeting thrombotic and inflammatory mechanisms, multilayered polymers for multiple-drug release and antigen–antibody coatings to capture endothelial cells are being searched for. Hopefully, the future control of complex biological mechanisms leading to atherosclerosis will eliminate the need for PCI. For the time being, interventional cardiology is here to stay and current research will make it even safer for the patient.

References

  1. Morice M-C, Serruys PW, Sousa JE, et al., for the RAVEL Study Group, A randomised comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization, N Eng J Med, 2002;346:1773–80.
    Crossref | PubMed
  2. Moses JW, Leon MB, Popma JJ, et al., for the SIRIUS Investigators, Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery, N Eng J Med, 2003;349:1315–23.
    Crossref | PubMed
  3. Schofer J, Schlüter M, Gershlick AH, et al., for the E-SIRIUS Investigators, Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS), Lancet, 2003;362:1093–9.
    Crossref | PubMed
  4. Schampaert E, Cohen EA, Schlüter M, et al., for the C-SIRIUS Investigators, The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS), J Am Coll Cardiol, 2004;43: 1110–15.
    Crossref | PubMed
  5. Mauri L, Orav EJ, O´Malley AJ, et al., Relationship of late loss in lumen diameter to coronary restenosis in sirolimus-eluting stents, Circulation, 2005;111:321–7.
    Crossref | PubMed
  6. Valgimigli M, Percoco G, Malagutti P, et al., for the SRATEGY Investigators, Tirofiban and sirolimus-eluting stent versus abciximab and bare-metal stent for acute myocardial infarction. A randomised trial, JAMA, 2005;295:2109–17.
  7. Spaulding C, Henry P, Teiger E, et al., for the TYPHOON Investigators, Sirolimus-eluting versus uncoated stents in acute myocardial infarction, N Eng J Med, 2006;355:1093–1104.
    Crossref | PubMed
  8. Menichelli M, Parma A, Pucci E, et al., Randomized trial of sirolimus-eluting stent versus bare-metal stent in acute myocardial infarction (SESAMI), J Am Coll Cardiol, 2007;49: 1924–30.
    Crossref | PubMed
  9. Ardissino D, Cavallini C, Bramucci E, et al., for the SES-SMART Investigators, Sirolimus-eluting versus uncoated stents for prevention of restenosis in small coronary arteries. A randomized trial, JAMA, 2004;292:2727–34.
    Crossref | PubMed
  10. Mehilli J, Dibra A, Kastrati A, et al., for the Intracoronary Drug-Eluting to Abrogate Restenosis in Small Arteries (ISAR-SMART III) Study Investigators, Randomized trial of paclitaxel- and sirolimus-eluting stents in small coronary vessels, Eur Heart J, 2006;27:260–66.
    Crossref | PubMed
  11. Kim YH, Park SW, Lee SW, et al., Sirolimus-eluting stent versus paclitaxel-eluting stent for patients with long coronary artery disease, Circulation, 2006;114:2148–53.
    Crossref | PubMed
  12. Vermeersch P, Agostoni P, Verheye S, et al., Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts. Six-month angiographic, intravascular ultrasound, and clinical follow-up of the RRISC Trial, J Am Coll Cardiol, 2006;48:2423–31.
    Crossref | PubMed
  13. Dibra A, Kastrati A, Alfonso F, et al., Effectiveness of drug-eluting stents in patients with bare-metal in-stent restenosis, J Am Coll Cardiol, 2007;49:616–23.
    Crossref | PubMed
  14. Spaulding C, Daemen J, Boersma, et al., A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents, N Eng J Med, 2007;356:989–97.
    Crossref | PubMed
  15. Mauri L, Hsieh V-H, Massaro JM, et al., Stent thrombosis in randomised clinical trials of drug-eluting stents, N Eng J Med, 2007;356:1020–29.
    Crossref | PubMed
  16. Kastrati A, Mehilli J, Pache J, et al., Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents, N Eng J Med, 2007;356:1030–39.
    Crossref | PubMed
  17. Stettler C, Wandel S, Allemann S, et al., Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis, Lancet, 2007;370:937–48.
    Crossref | PubMed
  18. Schömig A, Dibra A, Windecker S, et al., A meta-analysis of 16 randomized trials of sirolimus-eluting stents versus paclitaxel-eluting stents in patients with coronary artery disease, J Am Coll Cardiol, 2007;50:1373–80.
    Crossref | PubMed
  19. Marroquin OC, Selzer F, Mulukutla SR, et al., A comparison of bare-metal and drug-eluting stents for off-label indications, N Eng J Med, 2008;358:342–52.
    Crossref | PubMed
  20. Grines CL, Bonow RO, Casey DE, et al., Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents, Circulation, 2007;115: 813–18.
    Crossref | PubMed
  21. Takebayashi H, Kobayashi Y, Mintz GS, et al., Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation, Am J Cardiol, 2005;95: 498–502.
    Crossref | PubMed
  22. Hong M-K, Mintz GS, Lee CW, et al., Impact of late drug-eluting stent malapposition on three-year clinical events, J Am Coll Cardiol, 2007;50:1515–16.
    Crossref | PubMed
  23. Degertekin M, Serruys PW, Tanabe K, et al., Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis, Circulation, 2003;108: 2747–50.
    Crossref | PubMed
  24. Cuisser T, Hamilos M, Melikian N, et al., Direct stenting for stable angina pectoris is associated with reduced periprocedural microcirculatory injury compared with stenting after pre-dilation, J Am Coll Cardiol, 2008;51:1060–65.
    Crossref | PubMed
  25. Aoki J, Abizaid AC, Serruys PW, et al., Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients, J Am Coll Cardiol, 2005;46: 1670–76.
    Crossref | PubMed
  26. Virmani R, Guagliumi G, Farb A, et al., Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent. Should we be cautious?, Circulation, 2004;109:701–5.
    Crossref | PubMed
  27. Meier P, Zbinder R, Togni M, et al., Coronary collateral function long after drug-eluting stent implantation, J Am Coll Cardiol, 2007;49:15–20.
    Crossref | PubMed
  28. Takano M, Ohba T, Inami S, et al., Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after six-month implantation, Eur Heart J, 2006;27:2189–95.
    Crossref | PubMed
  29. Oyabu J, Ueda Y, Ogasawara N, et al., Angioscopic evaluation of neointima coverage: sirolimus drug-eluting stent versus bare metal stent, Am Heart J, 2006;152:1168–74.
    Crossref | PubMed
  30. Beusekom HMM, Saia F, Zindler JD, et al., Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus, Eur Heart J, 2007;28:974–9.
    Crossref | PubMed
  31. Togni M, Windecker S, Cocchia R, et al., Sirolimus-eluting stents associated with paradoxic coronary vasoconstriction, J Am Coll Cardiol, 2005;46:231–6.
    Crossref | PubMed
  32. Hofma SH, van der Giessen WJ, van Dalen BM, et al., Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation, Eur Heart J, 2006;27:166–70.
    Crossref | PubMed
  33. Kim JW, Suh SY, Choi CU, et al., Six-month comparison of coronary endothelial dysfunction associated with sirolimus-eluting stent versus paclitaxel-eluting stent, J Am Coll Cardiol Intv, 2008;1:65–71.
    Crossref | PubMed